

Bobrick B-7128 208-240V AC
Durable, 22-gauge, type 304 satin-finish stainless steel cover with black plastic trim, automatic operation, dual air outlets.
Wall Preparation
Use the provided template to locate the mounting base on the wall.
For brick, stone, or concrete walls:
- Drill four 0.315" (8mm) holes to fit wall plugs (0.315" x 1-1/4" or 8mm x 45mm) and screws (#10, 4.8mm x 2" or 50mm long).
- Refer to the template for wall plug and screw installation details.
For plaster or drywall:
- Ensure concealed backing complies with local building codes.
- Secure with four #10 (4.8mm) round-head sheet-metal screws or 3/16" (5mm) toggle bolts (not included).
Provide electrical service from the nearest distribution panel to the mounting base according to local electrical codes.
Wiring Instructions
For 115-Volt Dryers:
- Connect the ground wire to the terminal marked with a ground symbol.
- Connect the black (hot) wire to the terminal marked L1.
- Connect the neutral (white) wire to the terminal marked N.
For 208–240-Volt Dryers:
- Connect the ground wire to the terminal marked with a ground symbol.
- Connect the 208–240-volt wires to terminals L1 and L2.
Notes
- The electronic sensor in automatic dryers detects movement within 6" (150mm) of the air-outlet opening.
- Avoid installing the dryer in confined areas or close to doorways and high-traffic spaces to prevent accidental activation.