Troubleshooting: Water Stream is Too Low
Article Details
PROBLEM | CAUSE | CORRECTIVE ACTION | |
---|---|---|---|
Stream is too low after initial installation of the product. | 1 | Water pressure is lower then factor test conditions. | Remove sealant & use Teflon tape or compression fitting. |
2 | Press bar adjustment screw has not been adjusted for EHF, WC, HAC, or EMABF series water coolers. | Refer to manual & adjust press bar adjustment screw. | |
3 | Solenoid will not open up all of the way on EZ, HTV or electronic eye models. | Replace solenoid. | |
4 | Strainer screen is plugged with debris. | Clean or replace strainer screen. | |
5 | Water cooler has an added filter that is restricted. | Replace filter. |
PROBLEM | CAUSE | CORRECTIVE ACTION | |
---|---|---|---|
Regulator screw is turned all of the way clockwise and the flow is still too low. |
1 | Water shut off valve is not open all of the way. | Open shut off valve all of the way. |
2 | Regulator valve is defective or restricted with debris. | Replace regulator. | |
3 | A flexible water line is kinked within the water cooler. | Remove insulation from the line & remove the kink. | |
4 | Strainer screen is plugged with debris. | Clean or replace strainer screen. | |
5 | Water cooler has an added filter that is restricted. | Replace filter. |