Everpure Endurance SC High Flow Twin 1.0 (EV943740) Water Filtration System

The Pentair Everpure Endurance SC High Flow Twin 1.0 is a high-capacity commercial water filtration system engineered for demanding foodservice environments, delivering exceptional water quality with proprietary Fibredyne II media that reduces chlorine taste and odor while micro-filtering particulates down to 0.2 microns for consistent beverage excellence and equipment protection.

Performance & Specifications

Feature Specification
Model Number EV943740
Filtration Capacity 100,000 gallons (378,541 L)
Number of Filters Twin configuration with HFUF, 2 SEN cartridges, 1 2SR-BW cartridge
Flow Rate 7.5 GPM (28.4 Lpm)
Micron Rating 0.2 microns
Contaminants Filtered Chlorine taste & odor, cysts (Cryptosporidium & Giardia), particulates, scale

Key Features

  • Extended Service Life: High-capacity design allows for 6 to 12-month cartridge change-out intervals based on usage, reducing maintenance frequency
  • Multi-Stage Filtration: Features hollow fiber ultrafilter (HFUF) pretreatment, dual SEN fine filters, and 2SR-BW scale inhibitor for comprehensive water treatment
  • NSF Certified Performance: Certified under NSF/ANSI Standards 42 and 53, including cyst reduction for Cryptosporidium and Giardia
  • Fibredyne II Technology: Proprietary media effectively inhibits bacterial growth on filter media while reducing chlorine taste and odor for superior beverage quality
  • Commercial-Grade Construction: Operates at pressures from 50-100 psi and temperatures from 35-100°F, designed for continuous foodservice applications
  • Integrated Storage System: Includes 42.4 lb capacity storage tank assembly with automated control for consistent water supply during peak demand periods

FAQ


Q: What is the estimated cartridge replacement schedule for the Endurance SC High Flow Twin 1.0?

A: The SEN cartridge service life is 100,000 gallons or 6 to 12 months based on usage patterns. The HFUF hollow fiber ultrafilter has an approximately 3-year service life. The 2SR-BW scale inhibitor cartridge should be replaced according to water hardness and usage conditions.

Q: What electrical requirements are needed for installation?

A: The system includes a low-voltage transformer that plugs into a standard outlet (100-240 VAC/50-60 Hz input, 24 VDC 2.7 Amp output). It requires a 5 amp minimum branch circuit protection and should be installed on a GFI, RCD, or equivalent protected circuit. The electrical cord is 5 feet long.

Q: Can this system handle high-volume foodservice applications?

A: Yes, the Endurance SC High Flow Twin 1.0 is specifically designed for commercial foodservice environments with a rated service flow of 7.5 GPM (28.4 Lpm), making it suitable for multiple beverage dispensers, ice makers, and other high-volume equipment requiring consistent, quality water.


What's Included

  • Manifold with mounting bracket
  • Shroud and housing wrench
  • Hollow Fiber Ultrafilter (HFUF) in pretreatment housing
  • Two (2) SEN filter cartridges
  • One (1) 2SR-BW scale inhibitor cartridge
  • Storage tank assembly with 3/4" connection hose (15 inches)
  • Two (2) 3/8" tubing lengths (12 feet each) for flushing
  • 24 VDC electrical adapter with cord
  • O-rings, Oetiker clamps, plastic snap grips, and silicone grease
  • Two (2) port plugs for SEN cartridges
  • Installation, operation, and maintenance guide

Note: Only use this system with water that is known to be safe. If the water quality is uncertain, ensure it is disinfected before or after filtration.

Model Number: EV943740

System Type: Endurance SC High Flow Twin 1.0

Filtration Capacity: 100,000 gal (378,541 L)

Rated Service Flow: 7.5 GPM (28.4 Lpm)

Micron Rating: 0.2 microns

NSF Certifications: Standards 42 and 53

Operating Pressure: 50-100 psi (3.5-6.9 bar)

Operating Temperature: 35-100°F (2-38°C)

Inlet Connection: 3/4" (19 mm)

Outlet Connection: 3/4" FPT (19 mm)

Filter Configuration: HFUF + 2 SEN + 1 2SR-BW

Electrical Input: 100-240 VAC, 50-60 Hz

Electrical Output: 24 VDC, 2.7 Amp

Operating Weight (without tank): 64.65 lbs (29.3 kg)

Storage Tank Capacity: 42.4 lbs (19.3 kg) when full

Dimensions (W x H): 27" x 63" (68.9 x 160 cm)

Cartridge Change Interval: 6-12 months

HFUF Service Life: Approximately 3 years

Application: Commercial foodservice only

EPA Est. Number: 002623-IL-002

INSTALLATION

Install filter vertically. Allow space below for replacement. Insert into filter head and turn to lock. Flush thoroughly before first use. Contact professional if needed.

MAINTENANCE

Replace when flow slows or yearly. Flush new cartridge after installation. For ice machine use only. Contact service professional for performance issues.

Plumbers Paradise is a Top Seller on Amazon

Experience greater benefits by purchasing direct on PlumbersParadise.net

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare