Experience greater benefits by purchasing direct on PlumbersParadise.net
Everpure Insurice Single PF-i20002 (EV932421) Ice Machine Water Filtration System
The Everpure Insurice Single PF-i20002 (EV932421) delivers high-quality filtered water for commercial ice machines, featuring an integrated prefilter and 0.2-micron filtration that reduces scale buildup, cysts, and particulates to protect equipment and produce cleaner, fresher-tasting ice.
Performance & Specifications
| Feature | Specification |
|---|---|
| Model Number | Insurice Single PF-i20002 (EV932421) |
| Filtration Capacity | 9,000 gallons (34,069 L) |
| Number of Filters | 2 (i20002 cartridge + EC210 prefilter) |
| Flow Rate | Maximum 1.67 gpm (6.3 Lpm) |
| Contaminants Filtered | Chlorine taste & odor, cysts (Cryptosporidium & Giardia), particulates, scale, sediment |
Key Features
- ā Integrated Prefilter System: Includes EC210 prefilter cartridge that reduces dirt and particles before they reach the main filter, extending system life
- ā 0.2 Micron Filtration: Mechanical filtration removes particles as small as 0.2 microns, delivering exceptionally clean water for ice production
- ā Scale Reduction Technology: Reduces scale buildup from dissolved minerals to protect distribution lines, evaporator plates, and pumps from costly damage
- ā NSF/ANSI 53 Certified: Certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means for added safety
- ā Micro-Pure II Media: Proprietary filtration media inhibits bacterial growth on the filter that can decrease product life and performance
- ā Quick-Change Cartridges: Sanitary, easy cartridge replacement system minimizes downtime and simplifies maintenance procedures
FAQ
Q: What size ice machines is the Insurice Single PF-i20002 designed to support?
A: This system is designed for ice cubers producing up to 750 lbs. per day or flakers producing up to 1,500 lbs. per day, providing optimal filtration for commercial ice machine applications.
Q: How often should the cartridges be replaced on the EV932421 system?
A: Replace cartridges on a regular six-month preventative maintenance program, or when capacity is reached, or when pressure falls below 10 psi. The EC210 prefilter should be inspected periodically and replaced when dirt penetrates to the inner core.
Q: What are the installation requirements for this filtration system?
A: Install vertically with cartridges hanging down, use 3/4" water line (never saddle valves), ensure water pressure between 10-125 psi, allow 2.5" clearance below for cartridge replacement, and flush for 5 minutes at full flow during installation.
What's Included
- Insurice Single PF-i20002 system head (EV9324-21)
- i20002 replacement cartridge (EV9612-22)
- EC210 prefilter cartridge (EV9534-26)
- Mounting bracket and hardware
Note: Only use this system with water that is known to be safe. If the water quality is uncertain, ensure it is disinfected before or after filtration.